本文结合泰兴市四桥闸站工程,通过对工程初始方案与改进方案的数值模拟,分析了两种方案进水池内的流态。数值模拟结果表明:在设计流量下,(1)初始方案穿堤涵洞与泵站进水池连接形成侧向进水时,进水池内产生漩涡等不良流态,影响水泵安全稳定运行。(2)改进方案通过增加过渡段,改变了穿堤涵洞与进水池的连接方式,形成正向进水,进水池内无漩涡等不良流态,可以确保水泵安全稳定运行。
Abstract
Based on the numerical simulation of the initial scheme and the improvement scheme of TaiXing SiQiao combined sluice-pump station, this paper analyzes the pumping station intake sump flow patterns of the two schemes. The numerical simulation results show that: (1) The initial scheme flow of the pumping station intake sump appears side-direction, and the vortex and other bad flow patterns are generated in the intake sump, which affects the safe and stable operation of the pump. (2) The improvement scheme increased the transition section, which supplied the front inflow. And there were no vortex and other bad flow, so the pump can operate safe and stable.
关键词
穿堤涵洞 泵站 进水流态 数值模拟
{{custom_keyword}} /
Key words
culvert, pumping station, intake flow pattern, numerical simulation
{{custom_keyword}} /
{{custom_sec.title}}
{{custom_sec.title}}
{{custom_sec.content}}
参考文献
[1] 严登丰.泵站工程[M].北京:中国水利水电出版社,2005
[2] 陈德亮.水工建筑物[M].北京:中国水利水电出版社,2005.
[3] 成立,刘超,周济人等.泵站侧向进水流态及其改善措施机理探讨[J].排灌机械,2001,19(1):31~34.
[4] 张林,于永海,徐辉.侧向进水城市排水泵站配水池水力优化设计[J].中国给水排水,2008,24(8):37~40.
[5] 陆美凝.闸站结合泵站前池水流流态的数值模拟研究[D].硕士学位论文,扬州大学,2011.
[6] 金忠青,N-S方程的数值解及紊流模型[M].南京:河海大学出版社,1988:11-66.
[7] 王福军,计算流体动力学分析-CFD软件原理与应用[M].北京:清华大学出版社,2004:113-143.
[8] 陆林广,徐磊,梁金栋等.泵站进水流道三维流动及水力损失数值模拟[J].排灌机械,2008,26(5):55~58.