Analysis of Problems and Countermeasures on Water Quantity Measurement of Rural Water Supply Projects
SONG Wei-kun
,WU Xiao-mei
,LI Xiao-qin
,JIA Yan-nan
,LIAO Li-sha
Author information+
( 1.China Institute of Water Resources and Hydropower Research,Beijing 100048,China;
2. National Center for Efficient Irrigation Engineering and Technology Research,Beijing 100048,China
Measuring the quantity of water withdrawal and consumption of rural drinking water supply projects is the necessity of implementing of relevant laws and regulations, the necessity of practicing the strictest water resources management rules, and the necessity of guaranteeing the sustainable running of rural drinking water supply projects. Through the investigation of application of measuring equipment in rural drinking water supply projects in our country, ultrasonic flowmeter and electromagnetic flowmeter are the main measuring equipments of water works. And mechanical water meter, IC card intelligent water meter, and remote water meter are the main household water meters. At last, the reason of different installation rate and low accuracy were analyzed, and several suggestions were also put forward in order to improve water quantity measurement and promote sustainable running of rural drinking water supply projects.
SONG Wei-kun1,2
,WU Xiao-mei
1,2
,LI Xiao-qin1,2
,JIA Yan-nan1,2
,LIAO Li-sha1.
Analysis of Problems and Countermeasures on Water Quantity Measurement of Rural Water Supply Projects[J].China Rural Water and Hydropower, 2018(6): 118-121